← OSHA severe injury reports

Amputations

1 amputation · 2020021479 · 2/14/2020 · Abbot Diagnostics

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Finger(s), fingernail(s), n.e.c.
Nature of injury
Amputations

Cause

Event
Caught in running equipment or machinery during maintenance, cleaning
Source
Heating, cooling, and cleaning machinery and appliances, n.e.c.

Employer

Name
Abbot Diagnostics
Location
1921 Hurd Drive, IRVING, TEXAS, 75038
NAICS
339112
Jurisdiction
1

Narrative

An employee was working inside of the air handling unit and was working on the fan blade belt and pulley system. The employee rotated the fan blade pulley belt and amputated a finger between the fan blade and belt system. The air handling unit was not locked out/tagged out at the time of the incident.

Source

Authoritative
OSHA Severe Injury Reports
Machine