← OSHA severe injury reports
Fractures
1 hospitalization · 2020054770 · 5/22/2020 · Southern Skid Design and Fabrication
Severity
Hospitalized 1
Amputation 0
Loss of eye 0
Body part Face, unspecified
Nature of injury Fractures
Cause
Event Struck by discharged object or substance
Source Machine and appliance parts, n.e.c.
Secondary source Heating, cooling, and cleaning machinery and appliances, unspecified
Employer
Name Southern Skid Design and Fabrication
Location 4420 N Industrial Dr, CUMMING, GEORGIA, 30041
NAICS 332312
Jurisdiction 1
Narrative An employee was testing an HVAC system when the face of the pressure regulator blew off and hit the employee in the face. The employee suffered multiple fractures and lacerations to the face and a ruptured eardrum.
Source
Authoritative OSHA Severe Injury Reports
Machine JSON-LD · Markdown