← OSHA severe injury reports

Amputations

1 amputation · 2020065979 · 6/26/2020 · Honeywell Safety Products USA, Inc.

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Finger(s), fingernail(s), unspecified
Nature of injury
Amputations

Cause

Event
Caught in running equipment or machinery, n.e.c.
Source
Welding machinery

Employer

Name
Honeywell Safety Products USA, Inc.
Location
10 Thurber Boulevard, SMITHFIELD, RHODE ISLAND, 02917
NAICS
326199
Jurisdiction
1

Narrative

At about 4:00 a.m. on June 26, 2020, an employee was setting up a newly installed ultrasonic welder. While he was adjusting the head of the equipment on the mount relative to the welding plate, a gap was created between the head of the equipment and the welding fixture. When the computer recognized that the machine was too far out of adjustment, the welding fixture recoiled back up, closing the gap on the employee's left index finger. The finger was partially amputated.

Source

Authoritative
OSHA Severe Injury Reports
Machine