← OSHA severe injury reports

Amputations

1 amputation, 1 hospitalization · 2020098404 · 9/3/2020 · Accella Polyurethane Systems

Severity

Hospitalized
1
Amputation
1
Loss of eye
0
Body part
Fingertip(s)
Nature of injury
Amputations

Cause

Event
Caught in running equipment or machinery, n.e.c.
Source
Valves, nozzles

Employer

Name
Accella Polyurethane Systems
Location
2500 Adie Road, MARYLAND HEIGHTS, MISSOURI, 63043
NAICS
325211
Jurisdiction
1

Narrative

An employee was testing a three-way actuated valve assembly. When the ball cycled, it closed on the employee's left hand, amputating the tips of his middle and ring fingers.

Source

Authoritative
OSHA Severe Injury Reports
Machine
JSON-LD · Markdown