← OSHA severe injury reports

Amputations

1 amputation, 1 hospitalization · 2020098768 · 9/15/2020 · System One

Severity

Hospitalized
1
Amputation
1
Loss of eye
0
Body part
Finger(s), fingernail(s), unspecified
Nature of injury
Amputations

Cause

Event
Compressed or pinched by shifting objects or equipment
Source
Structural elements, n.e.c.
Secondary source
Towers, poles, n.e.c.

Employer

Name
System One
Location
8534 Hwy 89, SINTON, TEXAS, 78387
NAICS
561320
Jurisdiction
1

Narrative

A temporary employee was installing a structural steel brace for a cooling tower being erected. An unsupported brace slid off a column and the employee's right index and middle finger were pinched between the two. The employee suffered amputations to both fingers below the knuckles.

Source

Authoritative
OSHA Severe Injury Reports
Machine