← OSHA severe injury reports

Fractures

1 hospitalization · 20201010004 · 10/21/2020 · EMI Industries, LLC

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Finger(s), fingernail(s), unspecified
Nature of injury
Fractures

Cause

Event
Struck by swinging or slipping object, other than handheld, n.e.c.
Source
Table saws

Employer

Name
EMI Industries, LLC
Location
1316 TECH BOULEVARD, TAMPA, FLORIDA, 33619
NAICS
337127
Jurisdiction
1

Narrative

An employee was using a table saw to cut a 5-inch wide board into two 2-inch long pieces. As he was using a push stick, the cut piece moved under the push stick and kicked back and the 2-inch piece struck him in the right hand and fractured a knuckle.

Source

Authoritative
OSHA Severe Injury Reports
Machine