← OSHA severe injury reports

Amputations

1 amputation · 2020109626 · 10/9/2020 · Atlas Hydraulics Inc.

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Finger(s), fingernail(s), unspecified
Nature of injury
Amputations

Cause

Event
Caught in running equipment or machinery during maintenance, cleaning
Source
Bending, crimping machines

Employer

Name
Atlas Hydraulics Inc.
Location
700 East Redwood Boulevard, BRANDON, SOUTH DAKOTA, 57005
NAICS
332912
Jurisdiction
1

Narrative

An employee was operating a tube bender and noticed that one of the pressure dies was misaligned. The employee initiated a manual pause on the bender and then started adjusting the pressure die. A separate pressure die actuated, catching the employee's finger between the pressure die and a tube die causing injury to the distal phalanx of the right middle finger which required medical amputation.

Source

Authoritative
OSHA Severe Injury Reports
Machine