← OSHA severe injury reports

Amputations

1 amputation · 2020109937 · 10/19/2020 · Toshiba America Energy Systems Corporation

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Fingertip(s)
Nature of injury
Amputations

Cause

Event
Caught in running equipment or machinery, n.e.c.
Source
Cranes-gantry, overhead, monorail, container
Secondary source
Belts, gloves, neckties, scarves

Employer

Name
Toshiba America Energy Systems Corporation
Location
6623 West Washington Street, WEST ALLIS, WISCONSIN, 53214
NAICS
541690
Jurisdiction
1

Narrative

Two employees were inspecting the hoist cable on an overhead crane. One employee was operating the crane while the injured employee inspected the hoist cable. The injured employee was feeling the cable while it was moving through his gloved right hand checking for burrs or distortion in the cable when his fingers were caught between the crane cable and the pully of the block. Two fingertips were amputated.