← OSHA severe injury reports

Amputations

1 amputation · 2021054393 · 5/30/2021 · Astra Zeneca Pharmaceuticals, L.P.

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Fingertip(s)
Nature of injury
Amputations

Cause

Event
Caught in or compressed by equipment or objects, unspecified
Source
Machinery, unspecified

Employer

Name
Astra Zeneca Pharmaceuticals, L.P.
Location
1421 Beltline Dr., COPPELL, TEXAS, 75019
NAICS
325412
Jurisdiction
1

Narrative

A mechanic was performing preventative maintenance on an automated plunger type valve. The air pressure on the valve released and the valve closed due to spring pressure on it. The employee's left ring fingertip was caught between the valve and its seat resulting in amputation.

Source

Authoritative
OSHA Severe Injury Reports
Machine