← OSHA severe injury reports
Amputations
1 amputation · 2021064684 · 6/9/2021 · ATCO Products, Inc.
Severity
Hospitalized 0
Amputation 1
Loss of eye 0
Body part Finger(s), fingernail(s), unspecified
Nature of injury Amputations
Cause
Event Caught in running equipment or machinery during regular operation
Source Bending, crimping machines
Employer
Name ATCO Products, Inc.
Location 601 I-45 SOUTH, FERRIS, TEXAS, 75125
NAICS 336399
Jurisdiction 1
Narrative An employee placed a part on a CNC bend machine. The employee's right middle finger went into the bend machine along with the part, resulting in an amputation.