← OSHA severe injury reports

Fractures

1 hospitalization · 2021087417 · 8/30/2021 · Circor Refinery Valves

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Foot (feet), unspecified
Nature of injury
Fractures

Cause

Event
Struck by object falling from vehicle or machinery-other than vehicle part
Source
Parts and materials, unspecified
Secondary source
Slings

Employer

Name
Circor Refinery Valves
Location
16315 Market St., CHANNELVIEW, TEXAS, 77530
NAICS
332911
Jurisdiction
1

Narrative

An employee was working to lift and flip a 1,100-pound disc on a table to grind the opposite side. Softeners had been put between the disc and the sling because the disc had sharp edges. During the lift, the softeners slipped out and the nylon sling was sliced by the sharp edges of the disc. The disc then fell onto the employee's foot. The employee was hospitalized with a fractured foot.

Source

Authoritative
OSHA Severe Injury Reports
Machine