← OSHA severe injury reports

Amputations

1 amputation, 1 hospitalization · 20211210759 · 12/15/2021 · Kodiak Gas Services, LLC

Severity

Hospitalized
1
Amputation
1
Loss of eye
0
Body part
Finger(s), fingernail(s), n.e.c.
Nature of injury
Amputations

Cause

Event
Struck by object falling from vehicle or machinery-other than vehicle part
Source
Machine and appliance parts, n.e.c.
Secondary source
Machinery, unspecified

Employer

Name
Kodiak Gas Services, LLC
Location
Near TX 119 and CR 108 are the nearest cross roads, YORKTOWN, TEXAS, 78164
NAICS
213112
Jurisdiction
1

Narrative

Three employees were performing maintenance on a natural gas compressor. Part of the job was changing the belt on the cooler (fan) from the compressor. Prior to changing the fan's belt, an employee removed a section of the fan guard and set it over the compressor. The metal guard section was 3 feet by 2 feet and 8-inches thick and weighed approximately 40 lbs. The guard fell from the engine more than 5 feet and struck the injured employee's hand, resulting in amputation of their index finger.