← OSHA severe injury reports

Electrical burns, unspecified

1 hospitalization · 2022032440 · 3/17/2022 · Commercial Concrete Systems, LLC.

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Ankle(s)
Nature of injury
Electrical burns, unspecified

Cause

Event
Indirect exposure to electricity, greater than 220 volts
Source
Surfacing handtools-nonpowered, n.e.c.
Secondary source
Electrical wiring-building

Employer

Name
Commercial Concrete Systems, LLC.
Location
3080 Tamiami Trail East, NAPLES, FLORIDA, 34103
NAICS
238190
Jurisdiction
1

Narrative

An employee was finishing a concrete floor on the second level of a building. The bull float pole he was working with touched an electrical line and he suffered burns to the left ankle.

Source

Authoritative
OSHA Severe Injury Reports
Machine