← OSHA severe injury reports

Electrical burns, unspecified

1 hospitalization · 2022054253 · 5/16/2022 · EMSI, Inc.

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Upper and lower limb(s)
Nature of injury
Electrical burns, unspecified

Cause

Event
Indirect exposure to electricity, greater than 220 volts
Source
Lawn mowers-nonriding, powered
Secondary source
Power lines, transformers, convertors

Employer

Name
EMSI, Inc.
Location
Hendereed Village, COLUMBUS, OHIO, 43220
NAICS
541320
Jurisdiction
1

Narrative

An employee was operating a walk-behind mower when it struck a support/guy wire for a power pole. The guy wire began to whip and came in contact with an energized power line at the top of the power pole. Electricity travelled down the wire, through the machine, and shocked the employee. He was then thrown from the mower. The employee sustained electric shock and burns to the right hand and left big toe.

Source

Authoritative
OSHA Severe Injury Reports
Machine
JSON-LD · Markdown