← OSHA severe injury reports

Amputations

1 amputation · 2022064816 · 6/3/2022 · Yulista Integrated Solutions, LLC

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Finger(s), fingernail(s), n.e.c.
Nature of injury
Amputations

Cause

Event
Caught in running equipment or machinery during regular operation
Source
Milling machines
Secondary source
Belts, gloves, neckties, scarves

Employer

Name
Yulista Integrated Solutions, LLC
Location
7500 Advanced Gateway, HUNTSVILLE, ALABAMA, 35808
NAICS
336412
Jurisdiction
1

Narrative

An employee was maneuvering a part into a mill to deburr holes. The mill bit grabbed the employee's glove and amputated the first inch of their right index finger.

Source

Authoritative
OSHA Severe Injury Reports
Machine