← OSHA severe injury reports

First degree heat (thermal) burns

1 hospitalization · 2022075994 · 7/10/2022 · Cardinal Glass Industries, Inc.

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Neck, except internal location of diseases or disorders
Nature of injury
First degree heat (thermal) burns

Cause

Event
Ignition of vapors, gases, or liquids
Source
Chemicals and chemical products, unspecified
Secondary source
Welding, cutting, and blow torches

Employer

Name
Cardinal Glass Industries, Inc.
Location
515 Cardinal Parkway, DURANT, OKLAHOMA, 74701
NAICS
327211
Jurisdiction
1

Narrative

Three employees were removing a broken shaft from an auger. They were using a MAPP gas torch to expand the casing around the auger. Because the auger was not coming out of the casing, canned air was used on the shaft to constrict it. The canned air liquid ignited in the torch's open flame, and one employee suffered first-degree internal throat burns.

Source

Authoritative
OSHA Severe Injury Reports
Machine