← OSHA severe injury reports
Amputations
1 amputation, 1 hospitalization · 2022076676 · 7/29/2022 · Shawcor Pipeline Protection LLC
Severity
Hospitalized 1
Amputation 1
Loss of eye 0
Body part Finger(s), fingernail(s), n.e.c.
Nature of injury Amputations
Cause
Event Caught in running equipment or machinery during regular operation
Source Lathes, unspecified
Secondary source Sanders-nonpowered
Employer
Name Shawcor Pipeline Protection LLC
Location 817 Shields Rd., CHANNELVIEW, TEXAS, 77530
NAICS 332812
Jurisdiction 1
Narrative An employee was sanding a part on a lathe with sandpaper. The paper pulled his gloved right hand into the rotating shaft. He was hospitalized and his index finger was medically amputated.
Source
Authoritative OSHA Severe Injury Reports
Machine JSON-LD · Markdown
OSHA severe injury data · MORVS CC0 1.0