← OSHA severe injury reports

Amputations

1 amputation, 1 hospitalization · 2022086853 · 8/4/2022 · Hydro Extrusion USA LLC

Severity

Hospitalized
1
Amputation
1
Loss of eye
0
Body part
Finger(s), fingernail(s), unspecified
Nature of injury
Amputations

Cause

Event
Caught in running equipment or machinery during regular operation
Source
Presses, except printing, unspecified

Employer

Name
Hydro Extrusion USA LLC
Location
53 Pottsville Street, CRESSONA, PENNSYLVANIA, 17929
NAICS
331313
Jurisdiction
1

Narrative

An employee was broaching a keyway in a bore sprocket with a manually operated powered cylinder hydraulic press. On pressing the broach through the initial phase of cutting, he used an extension rod to finish broaching and clear the broach from the part. While setting up the extension rod, he placed his left index finger on top of the extension rod. The press extended and crushed his finger, resulting in an amputation.

Source

Authoritative
OSHA Severe Injury Reports
Machine