← OSHA severe injury reports

Heat (thermal) burns, unspecified

2 hospitalizations · 2022108794 · 10/6/2022 · Broadhead Boring, LLC

Severity

Hospitalized
2
Amputation
0
Loss of eye
0
Body part
Multiple body parts, unspecified
Nature of injury
Heat (thermal) burns, unspecified

Cause

Event
Ignition of vapors, gases, or liquids
Source
Natural gas

Employer

Name
Broadhead Boring, LLC
Location
Intersection of Dauer Ranch Road and Pieper Road, NEW BRAUNFELS, TEXAS, 78130
NAICS
213111
Jurisdiction
1

Narrative

Employees were making a tie-in on an 8-inch natural gas line by attaching two squeeze-off tools to shut off the line. When the polyethylene pipe was cut, one of the squeeze-off tools failed, causing a leak that resulted in an ignition. One employee was burned over about 50 percent of their body; the other was burned over about 10 percent.