← OSHA severe injury reports

Heat (thermal) burns, unspecified

1 hospitalization · 2022109345 · 10/25/2022 · Cardinal Communications, LLC

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Multiple body parts, unspecified
Nature of injury
Heat (thermal) burns, unspecified

Cause

Event
Vehicle or machinery fire
Source
Boom truck, bucket or basket hoist truck
Secondary source
Power lines, transformers, convertors

Employer

Name
Cardinal Communications, LLC
Location
HWY 98 1 Mile N of SR 51 going SB, STEINHATCHEE, FLORIDA, 32359
NAICS
238210
Jurisdiction
1

Narrative

An employee was on the ground, spotting a co-worker who was installing a fiber-optic cable while elevated in a bucket truck. As the strand of cable was raised, an attenuator snapped off the power pole with the 14.4 kV power line still attached and the power line fell onto the boom arm of the bucket truck. The truck became energized and caught on fire. The employee tried to bring their co-worker down but their hands and body were drawn against the controls of the truck and then the employee was thrown to the ground. The employee sustained electrical and thermal burns to over 75 percent of their body.

Source

Authoritative
OSHA Severe Injury Reports
Machine
JSON-LD · Markdown