← OSHA severe injury reports

Amputations

1 amputation · 2023032818 · 3/29/2023 · Prime Conduit, Inc.

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Finger(s), fingernail(s), unspecified
Nature of injury
Amputations

Cause

Event
Compressed or pinched by shifting objects or equipment
Source
Sawing machinery-stationary, n.e.c.

Employer

Name
Prime Conduit, Inc.
Location
17962 NW HWY 441, HIGH SPRINGS, FLORIDA, 32643
NAICS
335313
Jurisdiction
1

Narrative

On March 29, 2023, an employee was conducting maintenance on an upcut saw whose blade would not come up. He de-energized the saw and while the blade was slowing down, his left ring finger was caught between the pulley and belt inside the saw. The employee sustained an amputation to the finger without bone loss.

Source

Authoritative
OSHA Severe Injury Reports
Machine