← OSHA severe injury reports

Amputations

1 amputation · 2023054455 · 5/18/2023 · Empire Comfort Systems, Inc.

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Finger(s), fingernail(s), n.e.c.
Nature of injury
Amputations

Cause

Event
Caught in running equipment or machinery, unspecified
Source
Machinery, unspecified

Employer

Name
Empire Comfort Systems, Inc.
Location
918 Freeburg Avenue, BELLEVILLE, ILLINOIS, 62220
NAICS
333414
Jurisdiction
1

Narrative

An employee was working on a bander when his finger was caught in the pulley and belt, resulting in a right index finger amputation.