← OSHA severe injury reports

Electrocutions, electric shocks

1 hospitalization · 2023075973 · 7/6/2023 · Simmers Crane Design & Services

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
BODY SYSTEMS
Nature of injury
Electrocutions, electric shocks

Cause

Event
Direct exposure to electricity, greater than 220 volts
Source
Cranes-gantry, overhead, monorail, container

Employer

Name
Simmers Crane Design & Services
Location
17th Street and 2nd Avenue, HUNTINGTON, WEST VIRGINIA, 25703
NAICS
811310
Jurisdiction
1

Narrative

An employee was inspecting a double-girder overhead crane. As they were inspecting the crane wheel, they contacted a 480-volt alternating current (AC) power on the runway conductor bar. The electrical shock entered through the employee's left hand and exited through the torso. The employee was hospitalized.

Source

Authoritative
OSHA Severe Injury Reports
Machine