← OSHA severe injury reports

Electrocutions, electric shocks

1 hospitalization · 2023076105 · 7/10/2023 · Sentry View Systems

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
BODY SYSTEMS
Nature of injury
Electrocutions, electric shocks

Cause

Event
Direct exposure to electricity, greater than 220 volts
Source
Power lines, transformers, convertors

Employer

Name
Sentry View Systems
Location
Foxtrot Zero Four ICBM Minuteman Missile Site, RYDER, NORTH DAKOTA, 58779
NAICS
561621
Jurisdiction
1

Narrative

An employee was operating a boom lift when his head contacted a power line. He was shocked, the current exiting his body through his left arm.

Source

Authoritative
OSHA Severe Injury Reports
Machine