← OSHA severe injury reports

Fractures

1 hospitalization · 20231110765 · 11/22/2023 · Natura PCR 2

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Finger(s), fingernail(s), unspecified
Nature of injury
Fractures

Cause

Event
Caught in running equipment or machinery during regular operation
Source
Conveyors-belt
Secondary source
Belts, gloves, neckties, scarves

Employer

Name
Natura PCR 2
Location
18314 Mathis Rd, WALLER, TEXAS, 77484
NAICS
325991
Jurisdiction
1

Narrative

An employee was using a plastic rod to knock shredded polymer off the underside of a conveyor belt. The conveyor belt pulled the rod into the bottom frame. As the employee went to retrieve the rod, the belt pulled his right glove and his ring finger was lacerated and crushed between the belt and the frame. The finger was fractured and required hospitalization and surgery.

Source

Authoritative
OSHA Severe Injury Reports
Machine
JSON-LD · Markdown