1329 Markum Gate Way Rd., FORT WORTH, TEXAS, 76185
NAICS
333132
Jurisdiction
1
Narrative
An employee was using a CNC metal lathe machine in manual mode to check that the thread blocking tool made contact with the jaws. As the employee was manually spinning the spindle, his index fingertip was crushed between the spindle's jaws and the grooving insert, resulting in a fingertip amputation.