← OSHA severe injury reports

Amputations, avulsions, enucleations unspecified

1 amputation · 2024021413 · 2/14/2024 · ClimateMaster, Inc.

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Finger or thumb tip(s), nail(s)
Nature of injury
Amputations, avulsions, enucleations unspecified

Cause

Event
Struck by running powered equipment during maintenance, cleaning, testing
Source
Bending, crimping machinery
Secondary source
Gloves, handguards except disposable, electric insulating

Employer

Name
ClimateMaster, Inc.
Location
7300 SW 44TH Street, OKLAHOMA CITY, OKLAHOMA, 73179
NAICS
333415
Jurisdiction
1

Narrative

An employee was bending a piece of 5/8-inch copper tubing on a pipe bender machine. He noticed the machine was not bending the tube properly. As he was trying to correct the problem, his glove became caught, pulling his left index finger into the clamp die of the machine. His fingertip was crushed, resulting in an amputation.