← OSHA severe injury reports
Amputations, avulsions, enucleations unspecified
1 amputation, 1 hospitalization · 2024021509 · 2/17/2024 · Novo Precision LLC
Severity
Hospitalized 1
Amputation 1
Loss of eye 0
Body part Thumb(s)
Nature of injury Amputations, avulsions, enucleations unspecified
Cause
Event Caught, entangled in running powered equipment normal operation
Source Stationary drills, milling machinery
Secondary source Gloves, handguards except disposable, electric insulating
Employer
Name Novo Precision LLC
Location 150 Dolphin Road, BRISTOL, CONNECTICUT, 06010
NAICS 332618
Jurisdiction 1
Narrative An employee was cutting plastic tubes to length using a milling machine. His glove became entangled in the machine's rotating spindle, causing his hand to be drawn toward the endmill cutter. The top layer of his left thumb was amputated.