← OSHA severe injury reports

Amputations, avulsions, enucleations unspecified

1 amputation · 2024021622 · 2/21/2024 · Instrument Transformers, LLC

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Finger or thumb tip(s), nail(s)
Nature of injury
Amputations, avulsions, enucleations unspecified

Cause

Event
Struck by running powered equipment during maintenance, cleaning, testing
Source
Stamping machinery, presses except printing
Secondary source
Crowbars

Employer

Name
Instrument Transformers, LLC
Location
1907 Calumet Street, CLEARWATER, FLORIDA, 33765
NAICS
335929
Jurisdiction
1

Narrative

An employee was adjusting a mechanical press and using a prybar on the shaft to reset the cutter and crankshaft to the home position. The employee went to move the shaft, but it caught the flywheel with the momentum. This caused the shaft and prybar to spin around. The prybar struck his left middle fingertip and amputated it.

Source

Authoritative
OSHA Severe Injury Reports
Machine