← OSHA severe injury reports

Cuts, lacerations, punctures without injury to internal structures

1 hospitalization · 2024021842 · 2/29/2024 · Hycom Inc.

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Other finger(s) n.e.c.
Nature of injury
Cuts, lacerations, punctures without injury to internal structures

Cause

Event
Caught, entangled in running powered equipment normal operation
Source
Metal, woodworking, and special material machinery unspecified
Secondary source
Secondary source not applicable

Employer

Name
Hycom Inc.
Location
374 5th Street, BARBERTON, OHIO, 44203
NAICS
333611
Jurisdiction
1

Narrative

An employee was operating the flaring machine. While loading/adjusting a part in the machine, the foot control was activated and the employee's fingers were caught in the clamping mechanism. The employee sustained injuries to their left index and middle fingers requiring a skin graft and stitches, and was hospitalized.

Source

Authoritative
OSHA Severe Injury Reports
Machine