← OSHA severe injury reports
Amputations, avulsions, enucleations unspecified
1 amputation · 2024032629 · 3/24/2024 · Cerro Wire, LLC
Severity
Hospitalized 0
Amputation 1
Loss of eye 0
Body part Finger or thumb tip(s), nail(s)
Nature of injury Amputations, avulsions, enucleations unspecified
Cause
Event Caught, entangled in running powered equipment normal operation
Source Welding machinery
Secondary source Secondary source not applicable
Employer
Name Cerro Wire, LLC
Location 1099 Thompson Rd, SE, HARTSELLE, ALABAMA, 35640
NAICS 335929
Jurisdiction 1
Narrative An employee was operating a wire welder when the air actuated welder wire holding arm closed and pinched his right index finger, resulting in a fingertip amputation.
Source
Authoritative OSHA Severe Injury Reports
Machine JSON-LD · Markdown
OSHA severe injury data · MORVS CC0 1.0