← OSHA severe injury reports

Electrocution, electric shock

1 hospitalization · 2024032771 · 3/28/2024 · Atlas Industries Inc

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
BODY SYSTEMS
Nature of injury
Electrocution, electric shock

Cause

Event
Indirect exposure to electricity unspecified
Source
Electrical wiring building or machine
Secondary source
Trusses, girders, beams structurally attached

Employer

Name
Atlas Industries Inc
Location
10055 NW 12th Street, DORAL, FLORIDA, 33172
NAICS
238910
Jurisdiction
1

Narrative

An employee was working from a scissor lift during demolition of an internal wall on the second floor. He removed part of the drywall and intended to pull out a metal stud. A metallic electric conduit ran vertically in proximity of the stud. The conduit was not continuous, and a conduit section in the top part had been removed. A live unprotected cable lost insulation from contact with the stud, causing an electric discharge. The employee was electrocuted and hospitalized.

Source

Authoritative
OSHA Severe Injury Reports
Machine