← OSHA severe injury reports

Amputations, avulsions, enucleations unspecified

1 amputation · 2024054263 · 5/14/2024 · Imasen Bucyrus Technology, Inc.

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Finger or thumb tip(s), nail(s)
Nature of injury
Amputations, avulsions, enucleations unspecified

Cause

Event
Compressed between running equipment and other object(s)
Source
Hoists, lifts scissor, telescoping
Secondary source
Cranes gantry, overhead, monorail, container

Employer

Name
Imasen Bucyrus Technology, Inc.
Location
260 CROSSROADS BLVD., BUCYRUS, OHIO, 44820
NAICS
336399
Jurisdiction
1

Narrative

An employee was in a scissor lift. As the scissor lift rose, his left little and ring finger became caught between the scissor lift rail and a support beam for an overhead crane. His little finger sustained an amputation below the nail; his ring finger was lacerated and required stitches.

Source

Authoritative
OSHA Severe Injury Reports
Machine