← OSHA severe injury reports
Amputations, avulsions, enucleations unspecified
1 amputation · 2024064962 · 6/5/2024 · Idaho Milk Products, Inc.
Severity
Hospitalized 0
Amputation 1
Loss of eye 0
Body part Finger or thumb tip(s), nail(s)
Nature of injury Amputations, avulsions, enucleations unspecified
Cause
Event Struck by running powered equipment during maintenance, cleaning, testing
Source Dairy and milk processing machinery
Secondary source Valves, nozzles
Employer
Name Idaho Milk Products, Inc.
Location 2249 S Tiger Drive, JEROME, IDAHO, 83338
NAICS 424430
Jurisdiction 1
Narrative A maintenance employee was installing a mechanical valve in the raw milk intake bay and testing it for operation when his finger became caught in the valve. It was activated and amputated his fingertip.
Source
Authoritative OSHA Severe Injury Reports
Machine JSON-LD · Markdown
OSHA severe injury data · MORVS CC0 1.0