← OSHA severe injury reports

Amputations, avulsions, enucleations unspecified

1 amputation · 2024065248 · 6/13/2024 · Master-Halco, Inc.

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Finger or thumb tip(s), nail(s)
Nature of injury
Amputations, avulsions, enucleations unspecified

Cause

Event
Struck by running powered equipment during maintenance, cleaning, testing
Source
Extruding machinery
Secondary source
"Lock out/ tag out" communication systems

Employer

Name
Master-Halco, Inc.
Location
4633 E Radio Tower Ln, OLNEY, ILLINOIS, 62450
NAICS
332618
Jurisdiction
1

Narrative

An employee was fixing a jam in the wire extruding machine and caught the tip of their finger between the drum and roller on the wire roll up. The employee sustained a right ring fingertip amputation. The machine was not locked out/tagged out at the time.

Source

Authoritative
OSHA Severe Injury Reports
Machine