← OSHA severe injury reports

Electrocution, electric shock

1 hospitalization · 2024065298 · 6/15/2024 · E&M Services, LLC

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
BODY SYSTEMS
Nature of injury
Electrocution, electric shock

Cause

Event
Indirect exposure to electricity greater than 220 volts
Source
Power lines, transformers, convertors
Secondary source
Trucks with other mounted machinery, equipment n.e.c.

Employer

Name
E&M Services, LLC
Location
County Road 139, SIDNEY, MONTANA, 59270
NAICS
213112
Jurisdiction
1

Narrative

An employee was using a hydro-excavation truck on a cattle guard when the boom touched a 7,200-volt power line. The employee was hospitalized.

Source

Authoritative
OSHA Severe Injury Reports
Machine