← OSHA severe injury reports

Amputations, avulsions, enucleations unspecified

1 amputation · 2024065819 · 6/28/2024 · Vorteq Coil Finishers, LLC

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Finger or thumb tip(s), nail(s)
Nature of injury
Amputations, avulsions, enucleations unspecified

Cause

Event
Struck by running powered equipment during maintenance, cleaning, testing
Source
Painting, priming, metal coating machinery
Secondary source
Secondary source not applicable

Employer

Name
Vorteq Coil Finishers, LLC
Location
930 Armour Rd, OCONOMOWOC, WISCONSIN, 53066
NAICS
332812
Jurisdiction
1

Narrative

An employee was manually cleaning coater rolls when his right hand was pulled into the nip point. The employee sustained a degloving injury that resulted in surgical amputation of two fingertips.

Source

Authoritative
OSHA Severe Injury Reports
Machine