← OSHA severe injury reports
Amputations, avulsions, enucleations unspecified
1 amputation · 2024065819 · 6/28/2024 · Vorteq Coil Finishers, LLC
Severity
Hospitalized 0
Amputation 1
Loss of eye 0
Body part Finger or thumb tip(s), nail(s)
Nature of injury Amputations, avulsions, enucleations unspecified
Cause
Event Struck by running powered equipment during maintenance, cleaning, testing
Source Painting, priming, metal coating machinery
Secondary source Secondary source not applicable
Employer
Name Vorteq Coil Finishers, LLC
Location 930 Armour Rd, OCONOMOWOC, WISCONSIN, 53066
NAICS 332812
Jurisdiction 1
Narrative An employee was manually cleaning coater rolls when his right hand was pulled into the nip point. The employee sustained a degloving injury that resulted in surgical amputation of two fingertips.
Source
Authoritative OSHA Severe Injury Reports
Machine JSON-LD · Markdown
OSHA severe injury data · MORVS CC0 1.0