← OSHA severe injury reports

Amputations, avulsions, enucleations unspecified

1 amputation · 2024065857 · 6/30/2024 · Covenant Testing Technologies, LLC

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Finger or thumb tip(s), nail(s)
Nature of injury
Amputations, avulsions, enucleations unspecified

Cause

Event
Caught, entangled in running powered equipment normal operation
Source
Wrenches, ratchets
Secondary source
Rivets, bolts

Employer

Name
Covenant Testing Technologies, LLC
Location
HR Dalton Pad Site GPS Coordinates: 32'21'45.8" N 102?07'56.7"W, MIDLAND, TEXAS, 79707
NAICS
213112
Jurisdiction
1

Narrative

An employee was using a hydraulic torque wrench to remove bolts when their right index finger was caught between the torque wrench and bolt. The employee's right index fingertip was amputated.