← OSHA severe injury reports

Amputations, avulsions, enucleations unspecified

1 amputation · 2024076353 · 7/14/2024 · CB Manufacturing Company, Inc.

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Finger or thumb tip(s), nail(s)
Nature of injury
Amputations, avulsions, enucleations unspecified

Cause

Event
Struck by running powered equipment during maintenance, cleaning, testing
Source
Conveyors belt, slot, chain
Secondary source
"Lock out/ tag out" communication systems

Employer

Name
CB Manufacturing Company, Inc.
Location
510 West Skelly Drive, TULSA, OKLAHOMA, 74107
NAICS
312111
Jurisdiction
1

Narrative

An employee was performing maintenance on a chain drive for a conveyer belt motor. When the conveyor belt turned on, the chain drive contacted their left middle finger, resulting in a fingertip amputation. The conveyor was not locked out at the time of the incident.