← OSHA severe injury reports

Amputations, avulsions, enucleations unspecified

1 amputation, 1 hospitalization · 2024076564 · 7/18/2024 · James Hardie Building Products, Inc.

Severity

Hospitalized
1
Amputation
1
Loss of eye
0
Body part
Finger or thumb tip(s), nail(s)
Nature of injury
Amputations, avulsions, enucleations unspecified

Cause

Event
Struck by running powered equipment during maintenance, cleaning, testing
Source
Machinery unspecified
Secondary source
Valves, nozzles

Employer

Name
James Hardie Building Products, Inc.
Location
809 S Woodrow Wilson St, PLANT CITY, FLORIDA, 33563
NAICS
327320
Jurisdiction
1

Narrative

An employee was troubleshooting a process line. The metering valve was removed, but residual pneumatic energy was still present in the supply line. The employee was dislodging debris in the butterfly valve. Once the debris was dislodged, the valve closed, catching the employee's left middle finger and causing a fingertip amputation.

Source

Authoritative
OSHA Severe Injury Reports
Machine