← OSHA severe injury reports

Fractures

1 hospitalization · 2024076934 · 7/31/2024 · CANTEX INC.

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Arm(s) unspecified
Nature of injury
Fractures

Cause

Event
Struck by running powered equipment during maintenance, cleaning, testing
Source
Extruding machinery
Secondary source
Clamps, couplings

Employer

Name
CANTEX INC.
Location
202 Progress Rd, AUBURNDALE, FLORIDA, 33823
NAICS
326122
Jurisdiction
1

Narrative

An employee was working at an extrusion line and monitoring pipe as it came out of the extrusion machine. The employee went to prevent the production of a defective part and his hand passed through a sensor that triggered the action point for the machine. The machine's clamp came down to pick up the formed pipe and it fractured the employee's arm.

Source

Authoritative
OSHA Severe Injury Reports
Machine