← OSHA severe injury reports

Severe wounds, internal injuries and electrocution, electric shock

1 hospitalization · 2024087009 · 8/1/2024 · Ireland Electric Corporation

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Body systems and other part(s) of body
Nature of injury
Severe wounds, internal injuries and electrocution, electric shock

Cause

Event
Fall to lower level resulting from exposure or contact unspecified
Source
Portable ladders and stairs unspecified
Secondary source
Electrical wiring building or machine

Employer

Name
Ireland Electric Corporation
Location
2160 Mura Drive, AUGUSTA, GEORGIA, 30906
NAICS
238210
Jurisdiction
1

Narrative

An employee was on a ladder troubleshooting an emergency light that was out in the ceiling. He removed a wire nut and a live wire sprung back, hitting his finger and shocking him. The employee jumped and fell off the ladder onto his back on the floor. He lost consciousness and sustained a head laceration and fractured vertebrae. He was wearing insulated boots and using insulated equipment.