← OSHA severe injury reports

Multiple severe wounds and internal injuries

1 amputation · 2024087885 · 8/26/2024 · Tyson Foods, Inc.

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Finger or thumb tip(s), nail(s)
Nature of injury
Multiple severe wounds and internal injuries

Cause

Event
Struck by running powered equipment during maintenance, cleaning, testing
Source
Valves, nozzles
Secondary source
Secondary source not applicable

Employer

Name
Tyson Foods, Inc.
Location
5807 Mitchell Ave., SAINT JOSEPH, MISSOURI, 64507
NAICS
311612
Jurisdiction
1

Narrative

An employee was holding an actuator valve that was attached to air to keep it open, but it was depressurized and closed on his left middle finger. It amputated the tip of his finger and caused an open avulsion fracture of the last joint and an avulsed fingernail.

Source

Authoritative
OSHA Severe Injury Reports
Machine