← OSHA severe injury reports

Amputations, avulsions, enucleations unspecified

1 amputation · 2024087909 · 8/26/2024 · M & M Manufacturing, Inc.

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Finger or thumb tip(s), nail(s)
Nature of injury
Amputations, avulsions, enucleations unspecified

Cause

Event
Struck by running powered equipment during maintenance, cleaning, testing
Source
Bending, crimping machinery
Secondary source
Machine guards

Employer

Name
M & M Manufacturing, Inc.
Location
360 S Shiloh Rd,, GARLAND, TEXAS, 75042
NAICS
332322
Jurisdiction
1

Narrative

An employee was testing a cleat bender machine after repairing it and amputated their right middle fingertip. The machine was unguarded at the time.