← OSHA severe injury reports
Amputations, avulsions, enucleations unspecified
1 amputation · 2024098780 · 9/19/2024 · Vehtek Systems Inc.
Severity
Hospitalized 0
Amputation 1
Loss of eye 0
Body part Finger or thumb tip(s), nail(s)
Nature of injury Amputations, avulsions, enucleations unspecified
Cause
Event Struck by running powered equipment during maintenance, cleaning, testing
Source Stamping machinery, presses except printing
Secondary source Secondary source not applicable
Employer
Name Vehtek Systems Inc.
Location 2125 Wood-Bridge Blvd., BOWLING GREEN, OHIO, 43402
NAICS 336370
Jurisdiction 1
Narrative On September 19, 2024, an employee was assisting with a die changeover on a 2,000-ton press when the press was cycled, causing their hand to be pinched and resulting in an amputation to their ring fingertip.
Source
Authoritative OSHA Severe Injury Reports
Machine JSON-LD · Markdown
OSHA severe injury data · MORVS CC0 1.0