← OSHA severe injury reports

Amputations, avulsions, enucleations unspecified

1 amputation · 2024098909 · 9/24/2024 · Thru Tubing Solutions

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Finger or thumb tip(s), nail(s)
Nature of injury
Amputations, avulsions, enucleations unspecified

Cause

Event
Struck by suspended or swinging objects n.e.c.
Source
Pipes, ducts, tubing unspecified
Secondary source
Cranes unspecified

Employer

Name
Thru Tubing Solutions
Location
Hwy 182 and Plant Road, OPELOUSAS, LOUISIANA, 70570
NAICS
486210
Jurisdiction
1

Narrative

An employee was making a grease head connection. He pulled on the sling connected by a crane to balance the grease head. He was stabilizing the 5-1/2 lubricator with his left hand when the lubricator joint slipped into a tight space causing the 4-3/4 grease head to crush his left index finger against the lubricator. The employee's left index fingertip was amputated.

Source

Authoritative
OSHA Severe Injury Reports
Machine