← OSHA severe injury reports
Amputations, avulsions, enucleations unspecified
1 amputation, 1 hospitalization · 20241010113 · 10/30/2024 · Precise Food Ingredients
Severity
Hospitalized 1
Amputation 1
Loss of eye 0
Body part Thumb(s) and finger(s)
Nature of injury Amputations, avulsions, enucleations unspecified
Cause
Event Struck by running powered equipment during maintenance, cleaning, testing
Source Mixers, blenders, whippers food and beverage
Secondary source Secondary source not applicable
Employer
Name Precise Food Ingredients
Location 1432 Wainwright Way, CARROLLTON, TEXAS, 75007
NAICS 311942
Jurisdiction 1
Narrative An employee was cleaning the bottom of a blender and noticed something sticking out of the edge of the gate. He went to remove the object and the ribbon blade caused amputations to his left index finger and thumb.
Source
Authoritative OSHA Severe Injury Reports
Machine JSON-LD · Markdown
OSHA severe injury data · MORVS CC0 1.0