← OSHA severe injury reports

Amputations, avulsions, enucleations unspecified

1 amputation · 2024109213 · 10/2/2024 · Coreslab Structures (Omaha) Inc.

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Other finger(s) n.e.c.
Nature of injury
Amputations, avulsions, enucleations unspecified

Cause

Event
Struck by running powered equipment during maintenance, cleaning, testing
Source
Other metal, wood, and special material machinery n.e.c.
Secondary source
Machine hydraulics and pressurized components n.e.c.

Employer

Name
Coreslab Structures (Omaha) Inc.
Location
802 Allied Rd., BELLEVUE, NEBRASKA, 68123
NAICS
327390
Jurisdiction
1

Narrative

Two employees were using a stressing machine to pull and tension a cable to 3,000 pounds per square inch when the chuck assembly fell into the well of the hydraulic ram. They stopped stressing the cable and the injured employee retrieved the chuck and was positioning it in the well when the stressing machine was activated. The injured employee's right index and middle fingers were caught between the ram and the inside wall of the hydraulic ram, resulting in a partial index finger amputation and a fractured middle finger.

Source

Authoritative
OSHA Severe Injury Reports
Machine
JSON-LD · Markdown