An employee was troubleshooting a mini-feeder. As the employee was tapping the rotating drive chain with an Allen wrench, the employee's right hand came into contact with the chain. The employee suffered partial amputations, lacerations, and fractures to the middle and ring fingers. The machine was unguarded at the time of the incident.