← OSHA severe injury reports

Amputations, avulsions, enucleations unspecified

1 amputation · 20241110377 · 11/6/2024 · Belmark, Inc.

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Finger or thumb tip(s), nail(s)
Nature of injury
Amputations, avulsions, enucleations unspecified

Cause

Event
Struck by running powered equipment during maintenance, cleaning, testing
Source
Rollers, calenders, dryers paper production
Secondary source
Machine guards

Employer

Name
Belmark, Inc.
Location
633 Heritage Road, DE PERE, WISCONSIN, 54115
NAICS
323112
Jurisdiction
1

Narrative

An employee was operating a laminator and opened an interlocked guard to fix a crease in a web that was running. The employee's right little fingertip contacted a pinch point between the web and the roller and was amputated.

Source

Authoritative
OSHA Severe Injury Reports
Machine